전자부품 데이터시트 검색엔진
Selected language     Korean  ▼
부품명
         상세내용
Preview PDF Download HTML-1page HTML-10pages

KYL-815 데이터시트(Datasheet) 1 Page - SHENZHEN KYL COMMUNICATION EQUIPMENT CO,LTD.

부품명 KYL-815
상세내용  4-way wireless ON-OFFModule
PDF  5 Pages
Scroll/Zoom Zoom In 100% Zoom Out
제조사  KYL [SHENZHEN KYL COMMUNICATION EQUIPMENT CO,LTD.]
홈페이지  http://www.rf-data.com
Logo 

   
 1 page
background image
Shenzhen
Shenzhen
Shenzhen
Shenzhen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.,
.,
.,
., Ltd
Ltd
Ltd
Ltd
Tel:
Tel:
Tel:
Tel: +86-755-
+86-755-
+86-755-
+86-755-83410706
83410706
83410706
83410706
Email:
Email:
Email:
Email: sales0
sales0
sales0
sales01
1
1
1@rf-data.com
@rf-data.com
@rf-data.com
@rf-data.com
Web:
Web:
Web:
Web: www.rf-data.com
www.rf-data.com
www.rf-data.com
www.rf-data.com
KYL-815
KYL-815
KYL-815
KYL-815 4-way
4-way
4-way
4-way wireless
wireless
wireless
wireless ON-OFF
ON-OFF
ON-OFF
ON-OFF Module
Module
Module
Module
IIII.... Introduction
Introduction
Introduction
Introduction
This 4-way ON-OFF module is to transmit the ON-OFF condition to a remote place
wirelessly in time. When here the switch condition is ON, the output in the remote
place is ON. When the local switch condition is OFF, the other terminal is OFF.
KYL-815
KYL-815
II
II
II
II.... Features
Features
Features
Features of
of
of
of KYL-815
KYL-815
KYL-815
KYL-815
1. 4-way isolated input, high reliability and stability.
2. 4-way relay dry contact output, contact current is 220V, 5A.
3. Collocated with a wireless data module inside whose transmitting distance is about
 2 page
background image
Shenzhen
Shenzhen
Shenzhen
Shenzhen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.,
.,
.,
., Ltd
Ltd
Ltd
Ltd
Tel:
Tel:
Tel:
Tel: +86-755-
+86-755-
+86-755-
+86-755-83410706
83410706
83410706
83410706
Email:
Email:
Email:
Email: sales0
sales0
sales0
sales01
1
1
1@rf-data.com
@rf-data.com
@rf-data.com
@rf-data.com
Web:
Web:
Web:
Web: www.rf-data.com
www.rf-data.com
www.rf-data.com
www.rf-data.com
2km-3km; the working frequency 433MHz (400-470MHz); RF power: 1000mW;
4. Receiving sensitivity: -120dBm
5. Receiving current: 60mA; transmitting current: 350mA
6. Power supply: DC 12V-30V
7. Dimension: 95mm*90mm*40mm
III
III
III
III.... Dip
Dip
Dip
Dip Switch
Switch
Switch
Switch Instruction
Instruction
Instruction
Instruction
Pic 1. DIP Switch
DIP8
DIP8
DIP8
DIP8:Working
Working
Working
Working method
method
method
method
ON—input changes trigger transmission. Once you change any of the 4-way's
condition, the module will send out this info.
OFF---fixed time transmitting. The master transmits 4-way's condition to the
slave every 1s or 2s (not real-time transmitting).
DIP7
DIP7
DIP7
DIP7:Master
Master
Master
Master and
and
and
and slave
slave
slave
slave choosing
choosing
choosing
choosing under
under
under
under the
the
the
the fixed
fixed
fixed
fixed time
time
time
time transmitting
transmitting
transmitting
transmitting
mode
mode
mode
mode
ON—slave,OFF—master
DIP6
DIP6
DIP6
DIP6:Data
Data
Data
Data collecting
collecting
collecting
collecting mode
mode
mode
mode choosing
choosing
choosing
choosing
ON---
ON---
ON---
ON---Point to point transmission mode
OFF---
OFF---
OFF---
OFF---Data collection mode
The master collects input condition or controls output condition via sending data. In
data collecting mode, the module can't send out data actively. That is to say touch off
transmitting and fix time transmitting are both invalid at this mode.
DIP5
DIP5
DIP5
DIP5:Feedback
Feedback
Feedback
Feedback choice
choice
choice
choice
ON--
ON--
ON--
ON--feedback function close
OFF--
OFF--
OFF--
OFF--receiver will send back the received data to transmitter
DIP1-4
DIP1-4
DIP1-4
DIP1-4:Channel
Channel
Channel
Channel choosing
choosing
choosing
choosing
To avoid interference, please use different DIP switch mode and choose different
channels when you use several pairs of modules in the same place , Maximal 16
channels.
 3 page
background image
Shenzhen
Shenzhen
Shenzhen
Shenzhen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.,
.,
.,
., Ltd
Ltd
Ltd
Ltd
Tel:
Tel:
Tel:
Tel: +86-755-
+86-755-
+86-755-
+86-755-83410706
83410706
83410706
83410706
Email:
Email:
Email:
Email: sales0
sales0
sales0
sales01
1
1
1@rf-data.com
@rf-data.com
@rf-data.com
@rf-data.com
Web:
Web:
Web:
Web: www.rf-data.com
www.rf-data.com
www.rf-data.com
www.rf-data.com
The following is a channel correspondence table for DIP switch 1-4:
DIP
position
Channel
No
DIP
Ch.
DIP
Ch.
DIP
Ch.
1
5
9
13
2
6
10
14
3
7
11
15
4
8
12
16
Notice:
Notice:
Notice:
Notice:
* For most users "touch off transmitting mode" is OK-----DIP7-ON
* To avoid interference caused by more pairs of modules working in the same place,
please choose different channels for different systems.
* In timing mode, there should be a master and a slave.
* changing the DIP switch just takes effect after the module is re-powered on.
IV
IV
IV
IV.... Wiring
Wiring
Wiring
Wiring Terminal
Terminal
Terminal
Terminal Schematic
Schematic
Schematic
Schematic
Pic 2:Switch input wiring terminal schematic
 4 page
background image
Shenzhen
Shenzhen
Shenzhen
Shenzhen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.,
.,
.,
., Ltd
Ltd
Ltd
Ltd
Tel:
Tel:
Tel:
Tel: +86-755-
+86-755-
+86-755-
+86-755-83410706
83410706
83410706
83410706
Email:
Email:
Email:
Email: sales0
sales0
sales0
sales01
1
1
1@rf-data.com
@rf-data.com
@rf-data.com
@rf-data.com
Web:
Web:
Web:
Web: www.rf-data.com
www.rf-data.com
www.rf-data.com
www.rf-data.com
Pic 3: Switch output wiring terminal schematic
V
V
V
V.... Pin
Pin
Pin
Pin Definition:
Definition:
Definition:
Definition:
Port name
Pin No.
Definition
remarks
COM1
1
GND
GND
2
VCC
DC:12-30V
3
-
No conection
4
-
No connection
5
-
No connection
6
OUT1
1st way relay day contact output
7
8
OUT2
2nd way relay day contact output
9
10
OUT3
3rd way relay day contact output
11
12
OUT4
4th way relay day contact output
COM2
1
IN1
1st ON-OFF input
2
GND
3
IN2
2ns ON-OFF input
4
GND
5
IN3
3rd ON-OFF input
6
GND
7
IN4
4th ON-OFF input
8
GND
VI
VI
VI
VI.... How
How
How
How to
to
to
to use
use
use
use KYL-815
KYL-815
KYL-815
KYL-815
1. Consider your specific application, set the DIP switch, connect VCC (12V-30V
DC) and connect input and output cables as per the above instruction.
2. Power supply for the module.
 5 page
background image
Shenzhen
Shenzhen
Shenzhen
Shenzhen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.,
.,
.,
., Ltd
Ltd
Ltd
Ltd
Tel:
Tel:
Tel:
Tel: +86-755-
+86-755-
+86-755-
+86-755-83410706
83410706
83410706
83410706
Email:
Email:
Email:
Email: sales0
sales0
sales0
sales01
1
1
1@rf-data.com
@rf-data.com
@rf-data.com
@rf-data.com
Web:
Web:
Web:
Web: www.rf-data.com
www.rf-data.com
www.rf-data.com
www.rf-data.com
3. The factory setting is input changes trigger transmission mode and current
channel is No.1.
4. Choose different frequency points to avoid interference caused by more pairs of
modules working in the same area.
VII
VII
VII
VII.... About
About
About
About the
the
the
the LED
LED
LED
LED Indicator:
Indicator:
Indicator:
Indicator:
1. The power LED--It is always ON if modem is power supplied.
2. The data LED--It blinks once modem transmits or receives data
3. The working LED--It blinks every 1s, this indicates modem is working normally
4. The output LED--It's on indicates the corresponding output condition is connect.
It's off indicates the corresponding output condition is disconnect.
VIII
VIII
VIII
VIII.... Working
Working
Working
Working M
M
M
Mode
ode
ode
ode Instruction
Instruction
Instruction
Instruction
1. Touch off transmitting mode
Once there is any input change happens, the module will send it out. This mode
has the advantage of high speed, real-time transmission, and low power
consumption. Because module only transmits if there is input changes.
2. Fixed time transmitting mode
Under this mode, there should be one master and one slave module. The master
will synchronize with the slave every 1s, means the master will transmits its
condition to slave every 1S and the slave will transmits its condition to master
every 1S. If the master cannot synchronize with slave, the buzzer inside of module
will alarm. And all contacts will disconnect at the same time. This alarm will stop
automatically until the master is synchronize with slave again.
There will be at most 1s ON-OFF delay under this mode.




Html 페이지

1  2  3  4  5 


데이터시트




링크 URL

ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ]  

Alldatasheet는?   |   광고문의    |   운영자에게 연락하기   |   개인정보취급방침   |   즐겨찾기   |   링크교환   |   제조사별 검색
All Rights Reserved© Alldatasheet.com 2003 - 2017    


Mirror Sites
English : Alldatasheet.com  , Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp  |   Russian : Alldatasheetru.com
Korean : Alldatasheet.co.kr   |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com  |   Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl