상세내용  8-way wireless ON-OFFModule
PDF  5 Pages
Scroll/Zoom Zoom In 100% Zoom Out
제조사  KYL [SHENZHEN KYL COMMUNICATION EQUIPMENT CO,LTD.]
홈페이지  http://www.rf-data.com
Logo 

   
 1 page
background image
Shen
Shen
Shen
Shenz
z
z
zhen
hen
hen
hen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.
.
.
.,
,
,
, Ltd
Ltd
Ltd
Ltd
www.rf-data.com
sales02@rf-data.com
sales01@rf-data.com
KYL-818
KYL-818
KYL-818
KYL-818 8-
8-
8-
8-way
way
way
way wireless
wireless
wireless
wireless ON-OFF
ON-OFF
ON-OFF
ON-OFF Module
Module
Module
Module
IIII.... Introduction
Introduction
Introduction
Introduction
This 8-way ON-OFF module is to transmit the ON-OFF condition to a remote place
wirelessly in time. When here the switch condition is ON, the output in the remote
place is ON. When the local switch condition is OFF, the other terminal is OFF.
 2 page
background image
Shen
Shen
Shen
Shenz
z
z
zhen
hen
hen
hen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.
.
.
.,
,
,
, Ltd
Ltd
Ltd
Ltd
www.rf-data.com
sales02@rf-data.com
sales01@rf-data.com
II
II
II
II.... Features
Features
Features
Features of
of
of
of KYL-818
KYL-818
KYL-818
KYL-818
1、
8-way isolated input, high reliability and stability.
2、
8-way relay dry contact output, contact current is 220V, 5A.
3、
Collocated with a wireless data module inside whose transmitting distance
is about 2km-3km; the working frequency 433MHz (400-470MHz); RF
power: 1000mW; Receiving sensitivity: -123dBm
4、
Receiving current: 60mA; transmitting current: 350mA
5、
Power supply: DC 12V-30V
6、
Dimension: 145mm*90mm*40mm
III
III
III
III.... Dip
Dip
Dip
Dip switch
switch
switch
switch instruction
instruction
instruction
instruction
Pic 1. DIP Switch
DIP8
DIP8
DIP8
DIP8:working
working
working
working method
method
method
method
ON—touch off transmitting. Once you change any of the 8 channels condition,
the module will send out this info .
OFF---fixed time transmitting. The master transmits 8 channels' condition to the
slave every 1s or 2s (not real-time transmitting).
DIP7
DIP7
DIP7
DIP7:master
master
master
master and
and
and
and slave
slave
slave
slave choosing
choosing
choosing
choosing under
under
under
under the
the
the
the fixed
fixed
fixed
fixed time
time
time
time transmitting
transmitting
transmitting
transmitting mode
mode
mode
mode
ON—slave,OFF—host
DIP6
DIP6
DIP6
DIP6:data
data
data
data collecting
collecting
collecting
collecting mode
mode
mode
mode
The master collects input condition or controls output condition via sending data. In
data collecting mode, the module can't send out data actively. That is to say touch off
 3 page
background image
Shen
Shen
Shen
Shenz
z
z
zhen
hen
hen
hen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.
.
.
.,
,
,
, Ltd
Ltd
Ltd
Ltd
www.rf-data.com
sales02@rf-data.com
sales01@rf-data.com
transmitting and timing transmitting are both invalid in this mode.
DIP5
DIP5
DIP5
DIP5:ON--no
ON--no
ON--no
ON--no definition
definition
definition
definition
DIP1-4
DIP1-4
DIP1-4
DIP1-4:channel
channel
channel
channel choosing
choosing
choosing
choosing
To avoid interference, please use different DIP switch mode and choose different
channels when you use several pairs of modules in the same place. Maximal 16
channels.
The following is a channel correspondence table for DIP switch 1-4:
DIP No.
Channel
No.
DIP No.
Channel
No.
DIP No.
Channel
No.
DIP No.
Channel
No.
1
5
9
13
2
6
10
14
3
7
11
15
4
8
12
16
Notice:
Notice:
Notice:
Notice:
* For most users "touch off transmitting mode" is OK-----DIP7-ON
* To avoid interference caused by more pairs of modules working in the same place,
please choose different channels for different systems.
* In timing mode, there should be a master and a slave.
* changing the DIP switch just takes effect after the module is re-power on.
IV
IV
IV
IV.... Wiring
Wiring
Wiring
Wiring Terminal
Terminal
Terminal
Terminal Schematic
Schematic
Schematic
Schematic
 4 page
background image
Shen
Shen
Shen
Shenz
z
z
zhen
hen
hen
hen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.
.
.
.,
,
,
, Ltd
Ltd
Ltd
Ltd
www.rf-data.com
sales02@rf-data.com
sales01@rf-data.com
Pic 2:Switch input wiring terminal schematic
Pic 3: Switch output wiring terminal schematic
V
V
V
V.... Pin
Pin
Pin
Pin Definition:
Definition:
Definition:
Definition:
Pin name
Pin No.
Definition
Remarks
COM1
1
GND
The ground of power supply
2
VCC
DC:12-30V
3
-
Blank
4
-
Blank
5
OUT1
The 1st way dry contact output
6
7
OUT2
The 2nd way dry contact output
8
9
OUT3
The 3rd way dry contact output
10
11
OUT4
The 4th way dry contact output
12
13
OUT5
The 5th way dry contact output
14
15
OUT6
The 6th waydry contact output
16
17
OUT7
The 7th way dry contact output
18
19
OUT8
The 8th way dry contact output
 5 page
background image
Shen
Shen
Shen
Shenz
z
z
zhen
hen
hen
hen KYL
KYL
KYL
KYL Communication
Communication
Communication
Communication Equipment
Equipment
Equipment
Equipment Co
Co
Co
Co.
.
.
.,
,
,
, Ltd
Ltd
Ltd
Ltd
www.rf-data.com
sales02@rf-data.com
sales01@rf-data.com
20
COM2
1
IN1
The 1st ON-OFF condition input
2
GND
3
IN2
The 2nd ON-OFF condition input
4
GND
5
IN3
The 3rd ON-OFF condition input
6
GND
7
IN4
The 4th ON-OFF condition input
8
GND
9
IN5
The 5th ON-OFF condition input
10
GND
11
IN6
The 6th ON-OFF condition input
12
GND
13
IN7
The 7th ON-OFF condition input
14
GND
15
IN8
The 8th ON-OFF condition input
16
GND
VI
VI
VI
VI.... How
How
How
How to
to
to
to use
use
use
use KYL-818
KYL-818
KYL-818
KYL-818
1. Consider your specific application, set the DIP switch, connect VCC(12V-30V
DC) and switch input and output cables as per the above instruction.
2. Power supply on for the module.
3. The factory setting is touch off transmitting mode and current channel is No.1.
4. Choose different frequency points to avoid interference caused by more pairs of
modules working in the same area.




Html 페이지

1  2  3  4  5 


데이터시트




링크 URL

ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ]  

Alldatasheet는?   |   광고문의    |   운영자에게 연락하기   |   개인정보취급방침   |   즐겨찾기   |   링크교환   |   제조사별 검색
All Rights Reserved© Alldatasheet.com 2003 - 2017    


Mirror Sites
English : Alldatasheet.com  , Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp  |   Russian : Alldatasheetru.com
Korean : Alldatasheet.co.kr   |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com  |   Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl