전자부품 데이터시트 검색엔진 |
|
ST93CS46M6013TR 데이터시트(PDF) 6 Page - STMicroelectronics |
|
ST93CS46M6013TR 데이터시트(HTML) 6 Page - STMicroelectronics |
6 / 16 page POWER-ON DATA PROTECTION In order to prevent data corruption and inadvertent write operations during power up, a Power On Reset (POR) circuit resets all internal programming circuitry and sets the device in the Write Disable mode. When VCC reaches its functional value, the device is properlyreset (in the Write Disable mode) and is ready to decode and execute an incoming instruction. A stable VCC must be applied before any logic signal. INSTRUCTIONS The ST93CS46/47 has eleven instructions, as shown in Table 6. Each instruction is preceded by the rising edge of the signal applied on the Chip Select (S) input (assuming that the Clock C is low), followed by a ’1’ read on D input during the rising edge of the clock C. The op-codes of the instruc- tions are made up of the 2 following bits. Some instructions use only these first two bits, others use also the first two bits of the address field to define the op-code. The address field is six bits long (A5-A0). The ST93CS46/47 is fabricated in CMOS technol- ogy and is therefore able to run from zero Hz (static input signals) up to the maximum ratings (specified in Table 5). Read The Read instruction (READ) outputs serial data on the Data Output (Q). When a READ instruction is received, the instruction and address are de- coded and the data from the memory is transferred into an output shiftregister. A dummy ’0’ bit is output first followed by the 16 bit word with the MSB first. Instruction Description W Pin (1) PRE Pin Op Code Address (1) Data Additional Information READ Read Data from Memory X ’0’ 10 A5-A0 Q15-Q0 WRITE Write Data to Memory ’1’ ’0’ 01 A5-A0 D15-D0 Write is executed if the address is not inside the Protected area PAWRITE Page Write to Memory ’1’ ’0’ 11 A5-A0 D15-D0 Write is executed if all the addresses are not inside the Protected area WRALL Write All Memory ’1’ ’0’ 00 01XXXX D15-D0 Write all data if the Protect Register is cleared WEN Write Enable ’1’ ’0’ 00 11XXXX WDS Write Disable X ’0’ 00 00XXXX PRREAD Protect Register Read X ’1’ 10 XXXXXX Q8-Q0 Data Output = Protect Register content + Protect Flag bit PRWRITE Protect Register Write ’1’ ’1’ 01 A5-A0 Data above specified address A5-A0 are protected PRCLEAR Protect Register Clear ’1’ ’1’ 11 111111 Protect Flag is also cleared (cleared Flag = 1) PREN Protect Register Enable ’1’ ’1’ 00 11XXXX PRDS Protect Register Disable ’1’ ’1’ 00 000000 OTP bit is set permanently Note: 1. X = don’t care bit. Table 6. Instruction Set 6/16 ST93CS46, ST93CS47 |
유사한 부품 번호 - ST93CS46M6013TR |
|
유사한 설명 - ST93CS46M6013TR |
|
|
링크 URL |
개인정보취급방침 |
ALLDATASHEET.CO.KR |
ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |