Back Button ADM1033_12 Datasheet HTML 4Page - ON Semiconductor ADM1033_12 Datasheet HTML 5Page - ON Semiconductor ADM1033_12 Datasheet HTML 6Page - ON Semiconductor ADM1033_12 Datasheet HTML 7Page - ON Semiconductor ADM1033_12 Datasheet HTML 8Page - ON Semiconductor ADM1033_12 Datasheet HTML 9Page - ON Semiconductor ADM1033_12 Datasheet HTML 10Page - ON Semiconductor ADM1033_12 Datasheet HTML 11Page - ON Semiconductor ADM1033_12 Datasheet HTML 12Page - ON Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 35 page
background image
ADM1033
http://onsemi.com
8
Functional Description
The ADM1033 is a local- and remote-temperature
monitor and fan controller for use in a variety of
applications, including microprocessor-based systems. The
device accurately monitors remote and ambient temperature
and uses that information to quietly control the speed of a
cooling fan. Whenever a fan stalls, the device asserts a
FAN_FAULT output.
The ADM1033 features a THERM I/O. As an input, this
measures assertions on the THERM pin. As an output, it
asserts a low signal to indicate when the measured
temperature exceeds the programmed THERM temperature.
The ADM1033 communicates over an SMBus 2.0 interface.
Its LOCATION input determines which version of SMBus to
use, as well as the SMBus address (in fixed and discoverable
mode) and the LOCATION bits in the UDID (in ARP-capable
mode).
Internal Registers
Table 5 gives a brief description of the ADM1033’s
principal internal registers. For more detailed information
on the function of each register, refer to Table 35.
Serial Bus Interface
The ADM1033 communicates with the master via the
2-wire SMBus 2.0 interface. It supports two versions of
SMBus 2.0, determined by the value of the LOCATION
input’s resistors.
The first version is fully ARP-capable. This means that it
supports address resolution protocol (ARP), allowing the
master to dynamically address the device on powerup. It
responds to ARP commands such as “Prepare to ARP.”
The second SMBus version, fixed and discoverable, is
backwards compatible with SMBus 1.0 and 1.1. In this mode,
the ADM1033 powers up with a fixed address, which is
determined by the state of the LOCATION pin on powerup.
NOTE: When using the ADM1033, Addresses 0xC2 and 0xCA should
not be used by any other device on the bus.
Location Input
The LOCATION input is a resistor divider input. It has
multiple functions and can specify the SMBus version (in
fixed and discoverable or ARP-capable modes); the SMBus
address (in fixed and discoverable mode); and the LLL bits
(in UDID in ARP-capable mode).
Figure 15. Bootstrapping the LOCATION Input
ADM1033
PIN 13
VCC
GND
R1
R2
LOCATION
The voltage of this 8-level input is set by a potential
divider. The voltage on LOCATION is sampled on powerup
and digitized by the on-chip ADC to determine the
LOCATION input value. Because the LOCATION input is
sampled only at powerup, changes made while power is
applied have no effect.
SMBus 2.0 ARP-Capable Mode
In ARP-capable mode, the ADM1033 supports features
such as address resolution protocol (ARP) and unique device
identifier (UDID). The UDID is a 128-bit message that
describes the ADM1033’s capabilities to the master. The
UDID also includes a vendor specific ID for functionally
equivalent devices.
Figure 16. Setting Up Multiple ADM1033 Addresses
in SMBus 2.0 ARP-capable Mode
ADM1033 1
VCC
GND
ARP
LOCATION = 111
1.5 kW
ADM1033 2
ADM1033 3
ADM1033 4
ADM1033 5
ADM1033 6
ADM1033 7
ADM1033 8
ARP
LOCATION = 110
1 kW
ARP
LOCATION = 101
1 kW
ARP
LOCATION = 100
1 kW
FD
ADDRESS = 53h
1 kW
FD
ADDRESS = 52h
1 kW
FD
ADDRESS = 51h
1.5 kW
FD
ADDRESS = 50h
In SMBus 2.0 mode, this vendor specific ID is generated
by an on-chip random number generator. This should enable
two adjacent ADM1033s in the same system to powerup
with a different vendor specific ID, allowing the master to
identify the two separate ADM1033’s and assign a different
address to each.
The state of the LOCATION input on powerup is also
reflected in the UDID. This is useful when there is more than
one ADM1033 in the system, so the master knows which one
it is communicating with. The complete UDID is listed in
Table 7.
The SMBus 2.0 master issues both general and directed
ARP commands. A general command is directed at all ARP
devices. A directed command is targeted at a single device
once an address has been established. The PEC byte must be
used for ARP commands. (Refer to the Packet Error
Checking (PEC) section.)


유사한 부품 번호 - ADM1033_12

제조업체부품명데이터시트상세설명
logo
Analog Devices
ADM1033ARQ AD-ADM1033ARQ Datasheet
1Mb / 40P
   Thermal Monitor and Fan Speed (RPM) Controller
REV. 0
ADM1033ARQ-REEL AD-ADM1033ARQ-REEL Datasheet
1Mb / 40P
   Thermal Monitor and Fan Speed (RPM) Controller
REV. 0
ADM1033ARQ-REEL7 AD-ADM1033ARQ-REEL7 Datasheet
1Mb / 40P
   Thermal Monitor and Fan Speed (RPM) Controller
REV. 0
ADM1033ARQZ AD-ADM1033ARQZ Datasheet
1Mb / 40P
   Thermal Monitor and Fan Speed (RPM) Controller
REV. 0
logo
ON Semiconductor
ADM1033ARQZ ONSEMI-ADM1033ARQZ Datasheet
422Kb / 35P
   Thermal Monitor and Fan Speed (RPM) Controller
July, 2010 ??Rev. 2
More results

유사한 설명 - ADM1033_12

제조업체부품명데이터시트상세설명
logo
Analog Devices
ADM1034 AD-ADM1034 Datasheet
1Mb / 40P
   Thermal Monitor and Fan Speed (RPM) Controller
REV. 0
ADM1033 AD-ADM1033 Datasheet
1Mb / 40P
   Thermal Monitor and Fan Speed (RPM) Controller
REV. 0
logo
ON Semiconductor
ADM1033 ONSEMI-ADM1033 Datasheet
422Kb / 35P
   Thermal Monitor and Fan Speed (RPM) Controller
July, 2010 ??Rev. 2
ADM1034 ONSEMI-ADM1034 Datasheet
426Kb / 39P
   Thermal Monitor and Fan Speed (RPM) Controller
July, 2009 ??Rev. 3
ADT7490 ONSEMI-ADT7490_16 Datasheet
763Kb / 75P
   Remote Thermal Monitor and Fan Controller
January, 2016 ??Rev. 6
ADT7475 ONSEMI-ADT7475_13 Datasheet
539Kb / 58P
   Remote Thermal Monitor and Fan Controller
August, 2018 ??Rev. 8
ADT7460ARQ-REEL ONSEMI-ADT7460ARQ-REEL Datasheet
698Kb / 47P
   Remote Thermal Monitor and Fan Controller
September, 2013 ??Rev. 9
ADT7467 ONSEMI-ADT7467_12 Datasheet
754Kb / 72P
   Remote Thermal Monitor and Fan Controller
May, 2012 ??Rev. 4
NCT7491 ONSEMI-NCT7491 Datasheet
794Kb / 81P
   Remote Thermal Monitor and Fan Controller
November, 2015 ??Rev. 2
NCT7491 ONSEMI-NCT7491_16 Datasheet
791Kb / 80P
   Remote Thermal Monitor and Fan Controller
June, 2016 ??Rev. 3
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


데이터시트 다운로드

Go To PDF Page


링크 URL




개인정보취급방침
ALLDATASHEET.CO.KR
ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com