전자부품 데이터시트 검색엔진 |
|
KR12S33-1000 데이터시트(PDF) 1 Page - Wall Industries,Inc. |
|
KR12S33-1000 데이터시트(HTML) 1 Page - Wall Industries,Inc. |
1 / 3 page Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 KR/KRW Series 6 Watt DC/DC Converter Single and Dual Outputs 2:1 and 4:1 Wide Input Voltage Range FEATURES ● 6 Watts Output Power ● Output Current up to 1A ● High Efficiency up to 83% ● Fixed Switching Frequency ● Six-Sided Continuous Shield ● Standard 2 x 1 x 0.4 inch Package ● 2:1 and 4:1 Wide Input Voltage Range ● ISO9001 Certified Manufacturing Facilities ● Compliant to RoHS EU Directive 2002/95/EC ● Options: Positive Logic and Negative Logic Remote ON/OFF, Industrial Temperature SPECIFICATIONS: KR/KRW Series All specifications apply @ 25°C ambient unless otherwise noted INPUT SPECIFICATIONS Input Voltage Range KR .............................. 12V nominal input .............................. 9-18VDC 24V nominal input ............................ 18-36VDC 48V nominal input ............................ 36-75VDC KRW ........................... 24V nominal input .............................. 9-36VDC 48V nominal input ............................ 18-75VDC Input Filter ....................................................................................... Pi Type Input Surge Voltage (100ms max) ....... 12V input ..........................36 VDC 24V input ..........................50 VDC 48V input ........................100 VDC Input Reflected Ripple Current (nom. Vin and FL)........................20mAp-p Start Up Time (nom. Vin and constant resistive load)..............450ms max. Remote ON/OFF (Option) (See Note 6) (Positive Logic)............... DC-DC ON.............Open or 3.5V < Vr < 12V DC-DC OFF .............Short or 0V < Vr < 1.2V (Negative Logic) ............. DC-DC ON...............Short or 0V < Vr < 1.2V DC-DC OFF ...........Open or 3.5V < Vr < 12V Input Current of Remote Control Pin (nominal Vin) ........... -0.5mA ~ +1mA Remote Off State Input Current (nominal Vin) ..................................2.5mA OUTPUT SPECIFICATIONS Output Voltage ..............................................................................see table Voltage Accuracy (nominal Vin and full load) ...................................... ±1% Output Current ..............................................................................see table Output Power ......................................................................... 6 Watts max. Line Regulation (LL to HL at FL)....................................................... ±0.2% Load Regulation (no load to full load) .......... Single Output.............. ±0.2% Dual Output ................... ±1% Cross Regulation (Dual) (Asymmetrical load 25% / 100% FL) ............ ±5% Minimum Load ....................................................................................... 0% Ripple/Noise (20 MHz BW) ...........................................................50mVp-p Temperature Coefficient ................................................. ±0.02% / °C max. Transient Response Recovery Time 25% load step change.................................................... (Single) 200us FL to HL ±1% error band (Dual) 200us PROTECTION SPECIFICATIONS Over Load Protection (% of full load at nom. input) .................... 170% typ. Short Circuit Protection. ............................Continuous, automatic recovery GENERAL SPECIFICATIONS Efficiency ........................................................................................see table Switching Frequency KR..........................................................................................300KHz typ. KRW ......................................................................................200KHz typ. Isolation Voltage (Input to Output)......................................... 1600VDC min. Isolation Resistance ...............................................................10 9 ohms min. Isolation Capacitance ................................................................ 300pF max. ENVIRONMENTAL SPECIFICATIONS Operating Temperature Standard .................................................... -25°C ~ +85°C (with derating) “I” suffix (See Note 7)................................. -40°C ~ +85°C (non-derating) “I” suffix (KRW series)................................ -40°C ~ +85°C (with derating) Storage Temperature .......................................................... -55°C ~ +105°C Maximum Case Temperature ............................................................. 100°C Relative Humidity...................................................................5% to 95% RH Thermal Impedance (See Note 8) Natural Convection ............................................................. 12°C / Watt Natural Convection with Heat-Sink..................................... 10°C / Watt Thermal Shock ..................................................................... MIL-STD-810F Vibration ................................10~55Hz, 10G, 30 minutes along X, Y, and Z MTBF (See Note 1) .......................................................... 3.145 x 10 6 hours PHYSICAL SPECIFICATIONS Weight ..................................................................................... 27g (0.95 oz) Dimensions....................... 2.0 x 1.0 x 0.40 inches (50.8 x 25.4 x 10.2 mm) Case Material ..............................................................Nickel-coated copper Base Material...................................................Non-conductive black plastic Potting material..................................................................Epoxy (UL94-V0) Shielding......................................................................................... six-sided SAFETY & EMC Approvals and Standards .................. IEC60950-1, UL60950-1, EN60950-1 EMI .....................................EN55022 .............................................. Class A ESD ....................EN61000-4-2…….. …….Perf. Criteria B Radiated Immunity..............EN61000-4-3............... 10V/m Perf. Criteria A Fast Transient.....................EN61000-4-4................. ±2KV Perf. Criteria B Surge (See Note 9).............EN61000-4-5................. ±1KV Perf. Criteria B Conducted Immunity...........EN61000-4-6............ 10 Vrms Perf. Criteria A Due to advances in technology, specifications subject to change without notice Air ± 8KV Contact ± 6KV APPLICATIONS ● Measurement ● Wireless Network ● Telecom/Datacom ● Industry Control System ● Semiconductor Equipment |
유사한 부품 번호 - KR12S33-1000 |
|
유사한 설명 - KR12S33-1000 |
|
|
링크 URL |
개인정보취급방침 |
ALLDATASHEET.CO.KR |
ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |