38 / 502 page
Description
Reset
Type
Name
Bit/Field
Value to load into the SysTick Current Value Register when the counter reaches 0.
-
W1C
RELOAD
23:0
SysTick Current Value Register
Use the SysTick Current Value Register to find the current value in the register.
Description
Reset
Type
Name
Bit/Field
Software should not rely on the value of a reserved bit. To provide compatibility with
future products, the value of a reserved bit should be preserved across a
read-modify-write operation.
0
RO
reserved
31:24
Current value at the time the register is accessed. No read-modify-write protection is
provided, so change with care.
This register is write-clear. Writing to it with any value clears the register to 0. Clearing
this register also clears the COUNTFLAG bit of the SysTick Control and Status Register.
-
W1C
CURRENT
23:0
SysTick Calibration Value Register
The SysTick Calibration Value register is not implemented.
September 02, 2007
38
Preliminary
ARM Cortex-M3 Processor Core