7 / 9 page The STK400-050 has six power transistors, so the thermal resistance per transistor θj-c is 1.8°C / W. With an assured ambient temperature Ta of 50°C, the required radiator thermal resistance θc-a would be: From expression (1)' θc-a <(125–50)/42.5 <1.76 From expression (2)' θc-a <(150–50)/42.5–1.8/6 <2.05 To satisfy both, 1.76°C/W is the required radiator thermal resistance. Figure 2 illustrates Pd - PO when the VCC of STK400-050 is ±19V and RL is functioning at 3Ω. Pd = 51W (1/10 PO max = during 3W) From expression (1)' θc-a <(125–50)-51 <1.47 From expression (2)' θc-a <(150-50)/51-1.8/6 <1.66 To satisfy both, 1.47°C / W is the required radiator thermal resistance. This design example is based on a fixed voltage supply, and will require verification within your specific set environment. No. 4340-7/9 STK400-050 |
유사한 부품 번호 - STK401-130 |
|
유사한 설명 - STK401-130 |
|
|
링크 URL |
개인정보취급방침 |
ALLDATASHEET.CO.KR |
ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |