3 / 15 page DocID024382 Rev 2 3/15 STPS20200C Characteristics To evaluate the maximum conduction losses use the following equation: P = 0.6 x IF(AV) + 0.01 IF 2 (RMS) Note: More information is available in the application notes: AN604 Calculation of conduction losses in a power rectifier AN4021 Calculation of reverse losses in a power diode Table 4. Static electrical characteristics (per diode) Symbol Test conditions Min. Typ. Max. Unit IR (1) Reverse leakage current Tj = 25 °C VR = VRRM 15 µA Tj = 125 °C 1.3 7 mA Tj = 125 °C VR = 150 V 4.5 VF (1) Forward voltage drop Tj = 25 °C IF = 10 A 0.86 V Tj = 125 °C 0.64 0.70 V 1. Pulse test: tp = 380 µs, δ < 2% |
유사한 부품 번호 - STPS20200CFP |
|
유사한 설명 - STPS20200CFP |
|
|
링크 URL |
개인정보취급방침 |
ALLDATASHEET.CO.KR |
ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |